Queen Creek’s hazardous materials permit, and the site plan behind it.
The Town of Queen Creek charges a fire prevention permit to store or use hazardous materials above the fire code’s amounts, inspects hazardous occupancies every year, and wrote its own rule asking for permit drawings as CAD files. RevealBuilt measures the building and delivers CAD.
What Queen Creek publishes
The town’s Development Services fee schedule (effective 6 May 2024) lists these under Fire Prevention:
| Item | Fee |
|---|---|
| Operational permit to store, transport on site, dispense, use or handle hazardous materials above the fire code table amounts | $200 |
| Hazardous materials container or tank installation, single | $200 |
| Removal, single | $200 |
| Abandonment or placing out of service | $100 |
| High-risk occupancy: annual operating permit and inspection | $100 a year, plus $75 over 12,000 sq ft |
- Hazardous (Group H) occupancies are high risk, which means a permit and inspection every year. Medium-risk businesses are every two years and low-risk every three.
- A hazmat assessment fee may also apply, the schedule notes, without listing an amount.
- These are the town’s fees, not ours, and they change. Check the current schedule before you budget.
What the town code adds
Queen Creek adopted the 2021 International Fire Code and amended it in Town Code Section 7.2.12. Among the amendments:
- Electronic drawings for the Fire Department. A new Section 408 requires digital permit drawings for certain projects, submitted through the Building Safety Division. One- and two-family homes and their accessory structures are exempt.
- CAD format, full scale. The files are DWG, DXF or DGN, drawn at 1:1 in feet.
- A site plan showing the parking lot, building numbers, parking garages, fire lanes and hydrants.
- A construction permit for hazardous materials storage, for installing or modifying Group H occupancies and for gas cabinets.
- Appendix H is not adopted. The town code says appendices apply only when specifically adopted, and the fire code list stops at Appendix G. The code’s own Section 5001.5.1 still applies.
The amendments document is dated October 2022. Ask Building Safety which projects Section 408 covers before you rely on it.
The drawings
The town’s CAD files. Section 408 asks for the drawings in DWG, DXF or DGN at 1:1 scale, with a site plan showing the parking lot, building numbers, parking garages, fire lanes and hydrants. Our as-built drawings are delivered as DWG at full scale, so an existing building with no CAD on file can be measured and drawn to that format.
The fire code’s site plan. Where a hazardous materials management plan (HMMP) is required with a permit, International Fire Code Section 5001.5.1 calls for a facility site plan showing:
- Access to each storage and use area
- Emergency equipment
- Where responders meet your liaison
- Evacuation meeting points
- Tanks above and below ground, with their piping
- The hazard classes in each area
- Control areas, Group H areas and exterior storage and use areas
- Emergency exits
The state’s site map. ADEQ states that a site map is mandatory for every facility submitting a Tier II report, showing every way in and out, where substances are stored, and the general layout.
One scan of the building is the base for all three.
How RevealBuilt fits
- We scan the building once and draw a measured floor plan and site plan to scale, with north and the drawing date.
- We place what the list calls for that we can see on site: exits, access, emergency equipment, tanks, shut-offs.
- You or your consultant supply the chemical locations, hazard classes and control area boundaries, and we draw them in.
- We do not classify materials, prepare the inventory statement or the management plan, or file anything with Queen Creek.
A measured site map from one scan of the building is $500 plus $0.05 per square foot scanned, with no travel charge anywhere in Queen Creek. Map update when storage moves $250. A drawing set made to a fuller HMMP list is quoted by the site before we schedule. For Arizona facilities we also prepare the Tier II report: $995 per facility, up to 30 chemicals.
Does Queen Creek require a hazardous materials permit?
The town’s fee schedule lists a $200 operational permit to store, transport on site, dispense, use or handle hazardous materials in excess of the amounts in the fire code’s permit table.
How often are hazardous occupancies inspected?
Every year. The schedule puts hazardous (H) occupancies in the high-risk category, with an annual operating permit and occupancy inspection at $100 a year plus $75 for sites over 12,000 square feet.
What do tank permits cost?
The schedule lists $200 for a single hazardous materials container or tank installation, $200 for removal and $100 for abandonment or placing out of service. Flammable and combustible liquid tanks are listed separately.
Does Queen Creek ask for a site plan with the permit?
The fee schedule does not say. The town’s amended fire code (Section 408) requires electronic permit drawings for certain projects with a site plan showing the parking lot, building numbers, parking garages, fire lanes and hydrants, and International Fire Code Section 5001.5.1 calls for a facility site plan where a management plan is required. Ask the Fire Prevention Bureau what it wants with your application.
What file format does Queen Creek want?
Section 408 of the town’s amended fire code names DWG, DXF or DGN, drawn at 1:1 scale in feet. One- and two-family homes and their accessory structures are exempt.
Did Queen Creek adopt Appendix H?
No. The town code says fire code appendices apply only when specifically adopted, and its list for the 2021 International Fire Code runs from Appendix A to Appendix G.
Who do we ask at the town?
The Queen Creek Fire Prevention Bureau, 480-358-3371.
Does the state also want a site map?
If the facility files a Tier II report, yes. ADEQ states that a site map is mandatory with every Tier II report in its system, showing every way in and out, where substances are stored, and the general layout. Whether you must file is a question for ADEQ or your consultant.
Can one scan cover the Queen Creek drawing and the Tier II site map?
Yes. Both are drawn over the same measured floor plan, so one visit covers both. Your staff or your consultant supplies the chemical locations and hazard classes; we draw them in.
Sources, checked 28 November 2026: Town of Queen Creek Development Services Fee Schedule (effective 5/6/2024; Fire Prevention permits and inspection categories); Town of Queen Creek Town Code Chapter 7 amendments (dated 10/19/2022; 2021 International Fire Code, Section 7.2.12, Section 408); Town of Queen Creek Fire Permits, Fees and Inspections page; International Fire Code Section 5001.5.1; ADEQ Tier II Reporting page. The town’s code and schedule are the authority and it changes. RevealBuilt measures and draws. It is not a regulator and does not classify chemicals, prepare the HMIS or HMMP, or decide what you must file. For that, ask the Queen Creek Fire Prevention Bureau at 480-358-3371.
Related
Tier II reporting and site maps, Arizona Tier II site map requirements, RevealBuilt in Queen Creek, and all compliance site maps and floor plans.
City guides: Gilbert, Mesa, Chandler, Phoenix, Scottsdale, Tempe, Glendale, Peoria, Goodyear, Buckeye, Surprise, Avondale.