Goodyear’s hazardous materials inventory statement, and the plan that shows the control areas.
The Goodyear Fire Department’s inventory statement (HMIS) is filled out control area by control area, and the department can ask for a management plan when a building has several. That plan is a drawing job. RevealBuilt measures the building and draws it.
What Goodyear’s form asks for
- A separate HMIS for each control area, marked inside or outside.
- Every column completed. The form says all columns are required.
- For each chemical: the name from the safety data sheet, concentration, CAS number, hazard classification, physical state and NFPA 704 ratings.
- The actual amount: the most in use or storage at one time in that control area, in cubic feet for gases, gallons for liquids and pounds for solids. Quantities add up by hazard class.
- The allowable amount: the maximum allowable quantity for that control area, from the tables in Chapter 50 of the International Fire Code.
- Tanks: the number of above-ground tanks.
- A signature from the person responsible for the statement, with copies of the safety data sheets.
When a management plan is asked for
The form says a hazardous materials management plan (HMMP) may be required where there are multiple control areas, or when the Fire Code Official decides one is warranted by the type of chemicals or the complexity of the facility.
Control areas are the reason the drawing matters. The allowable quantity is counted per control area, so the statement only makes sense next to a plan that shows where each control area starts and stops.
The drawings
Goodyear’s form does not describe a site plan of its own. The drawing requirements come from the fire code, when the department asks for a management plan, and from the state.
The fire code’s site plan. Where a hazardous materials management plan (HMMP) is required, International Fire Code Section 5001.5.1 calls for a facility site plan. Appendix H of the code describes the storage map: a floor plan of each building that holds hazardous materials, on letter-size paper, with north marked and each storage and use area shown, hazardous waste included. It lists:
- Access to each storage and use area
- Emergency equipment
- Where responders meet your liaison
- Evacuation meeting points
- Tanks above and below ground, with their piping
- The hazard classes in each area
- Control areas, Group H areas and exterior storage and use areas
- Emergency exits
The state’s site map. ADEQ states that a site map is mandatory for every facility submitting a Tier II report, showing every way in and out, where substances are stored, and the general layout.
One scan of the building is the base for both drawings.
How RevealBuilt fits
- We scan the building once and draw a measured floor plan and site plan to scale, with north and the drawing date.
- We place what the list calls for that we can see on site: exits, access, emergency equipment, tanks, shut-offs.
- You or your consultant supply the chemical locations, hazard classes and control area boundaries, and we draw them in.
- We do not classify materials, prepare the inventory statement or the management plan, or file anything with Goodyear.
A measured site map from one scan of the building is $500 plus $0.05 per square foot scanned, with no travel charge anywhere in Goodyear. Map update when storage moves $250. A drawing set made to a fuller HMMP list is quoted by the site before we schedule. For Arizona facilities we also prepare the Tier II report: $995 per facility, up to 30 chemicals.
Who fills out a Goodyear HMIS?
The business. The Goodyear Fire Department form asks for the business name, address, phone, email and an after-hours emergency number, and is signed by the person responsible for creating the statement.
Why one statement per control area?
The form says a separate HMIS is to be filled out for each separate control area. The fire code counts allowable quantities per control area, so each one is totalled on its own.
When does Goodyear ask for an HMMP?
The form says one may be required where there are multiple control areas, or when the Fire Code Official considers it warranted because of the type of chemicals or the complexity of the facility.
Does the Goodyear form ask for a site plan?
Not by itself. Where a management plan is required, International Fire Code Section 5001.5.1 calls for a facility site plan, and the state requires a site map with every Tier II report.
Who do we ask at the city?
The Goodyear Fire Department, (623) 932-2300, 14455 W. Van Buren St., Suite E102.
Does the state also want a site map?
If the facility files a Tier II report, yes. ADEQ states that a site map is mandatory with every Tier II report in its system, showing every way in and out, where substances are stored, and the general layout. Whether you must file is a question for ADEQ or your consultant.
Can one scan cover the Goodyear drawing and the Tier II site map?
Yes. Both are drawn over the same measured floor plan, so one visit covers both. Your staff or your consultant supplies the chemical locations and hazard classes; we draw them in.
Sources, checked 28 November 2026: City of Goodyear Fire Department Hazardous Materials Inventory Statement (form and instructions; cites International Fire Code Chapter 50 and Table 5003.1.1); Goodyear Fire Department Business Permit Application (contact details); International Fire Code Section 5001.5.1; International Fire Code, 2024 edition, Appendix H (HMMP and HMIS instructions; the copy linked is the one the City of Tucson publishes); ADEQ Tier II Reporting page. The city’s form is the authority and it changes. RevealBuilt measures and draws. It is not a regulator and does not classify chemicals, prepare the HMIS or HMMP, or decide what you must file. For that, ask the Goodyear Fire Department at (623) 932-2300.
Related
Tier II reporting and site maps, Arizona Tier II site map requirements, RevealBuilt in Goodyear, and all compliance site maps and floor plans.
City guides: Gilbert, Mesa, Chandler, Phoenix, Scottsdale, Tempe, Glendale, Peoria, Buckeye, Surprise, Queen Creek, Avondale.