Scope a project
Guide · Arizona Tier II reporting

Arizona Tier II site map requirements: what ADEQ asks for.

Arizona now requires a site map with every Tier II chemical inventory report filed in myDEQ. ADEQ names three things the map must show and leaves the drawing itself up to you. This page sets out the rule, the list and the deadline, with sources.

The short answer

Who needs oneEvery facility submitting a Tier II report in myDEQ, with or without extremely hazardous substances above the threshold planning quantity
What it must showAll points of ingress and egress, locations in and around the facility where substances are stored, and the general layout of the facility
FormatNo drawing standard published. Uploaded as a file in myDEQ with the report
DueMarch 1 each year, with the report. The filing season opens January 1
Authority ADEQ cites40 CFR 370.10(b)(2)
Who asked for itFire agencies and Local Emergency Planning Committees (LEPCs) across Arizona

Why ADEQ made the map mandatory

A Tier II report tells responders what chemicals a facility holds and roughly how much. It does not show them where. ADEQ describes the site map as vital information for first responders during an incident, and fire agencies and LEPCs statewide asked for one with every report.

The request reaches every filer, including facilities with no extremely hazardous substances over the planning threshold. ADEQ relies on 40 CFR 370.10(b)(2), which sets the threshold at zero when an LEPC, the state commission or the fire department with jurisdiction requests Tier II information.

What to put on the map

The three items ADEQ lists:

  • All points of ingress and egress. Site gates and driveways, and the building’s exterior doors.
  • Locations in and around the facility where substances are stored. Indoor storage rooms and cabinets, process areas, outdoor tanks and yards. Key each one to the chemical names on the report.
  • The general layout of the facility. Buildings, the main interior areas and the property line.

Worth adding, though ADEQ does not list them. These are common on site plans other states require and on fire department pre-incident plans: a north arrow, the street name and address, latitude and longitude, the date drawn, utility shutoffs, the fire department connection, the nearest hydrant and a meeting point for responders. Your own fire department has the final say on what it wants to see, so ask.

Illustrative Tier II site map A fictional facility drawn the way a Tier II site map is laid out: the street and two gates, one building with a warehouse, production floor and office, four keyed chemical storage locations, an outdoor tank, utility shutoffs, the fire department connection, a hydrant, a north arrow and a legend. E EXAMPLE ROAD PROPERTY LINE GATE 1 (MAIN)GATE 2 (TRUCKS) OFFICEPRODUCTIONWAREHOUSE DOOR 1DOOR 2DOCKDOOR 3 ABCD EGW FH N LEGEND A Flammable liquids cabinet B Corrosives, drum storage C Battery charging area D Diesel tank, in containment E Electrical main G Gas shutoff W Water shutoff F Fire dept. connection H Hydrant Example Facility (fictional) 0000 E Example Rd Lat 33.0000, Long -111.0000 Drawn 2026-11-15 0 40 80 ft
Illustration only. On a phone, swipe the drawing sideways to see the legend. The facility, address and contents are made up. Your map shows your site, to scale, with the storage locations keyed to the chemicals on your own Tier II report.

Local rules can go further

ADEQ’s list is the statewide floor. A city or fire district can ask for more under its fire code. The Town of Gilbert, for one, sets its own reporting thresholds far below the state’s and uses the same filing system. See Gilbert hazardous materials reporting.

Have it drawn

RevealBuilt scans the building and draws the Tier II site map to scale on a measured floor plan, delivered as a PDF ready for myDEQ. $500 per facility plus $0.05 per square foot, yearly update $150. Book the visit by February 12 for the March 1 deadline.

Questions
Does every Arizona Tier II filer need a site map?

Yes. ADEQ states the site map requirement is mandatory for all facilities submitting Tier II reports in myDEQ. It applies whether or not the facility has extremely hazardous substances above the threshold planning quantity.

What must an Arizona Tier II site map include?

ADEQ lists all points of ingress and egress, the locations in and around the facility where substances are stored, and the general layout of the facility.

Is there a required format, scale or symbol set?

ADEQ does not publish one. The map is uploaded to myDEQ as a file with the report. A clean PDF is the safe choice. Check the upload screen in myDEQ for the file types and size it accepts.

What is the legal basis for requiring the map?

ADEQ cites 40 CFR 370.10(b)(2). Under that rule the reporting threshold is zero when a Local Emergency Planning Committee, the state commission or the fire department with jurisdiction asks a facility for Tier II information.

When is it due?

With the Tier II report, by March 1 each year. ADEQ describes the reporting season as January 1 through March 1, and the report covers chemicals on site during the previous calendar year.

Who uploads the map?

Whoever prepares the report in myDEQ: a company employee or a consultant the company has given access. A company official then certifies the report.

Do I need a new map every year?

The map should match the facility as it stands when you file. If storage locations, doors or the layout changed, update it. If nothing changed, confirm that and reuse it with the current date.

Can a hand sketch satisfy the requirement?

ADEQ does not require a professional drawing. A legible sketch that shows the three required items can be uploaded. A to-scale plan with a legend is easier for a fire crew to use and easier to keep current.

Sources, checked 15 November 2026: ADEQ Tier II Reporting page; ADEQ “EPCRA & Tier II Reporting” presentation, January 2025; 40 CFR 370.10(b)(2); Town of Gilbert Fire Prevention Regulation 18-5003.4.1 (revised 3/6/2024). RevealBuilt draws the map. It is not a regulator and does not decide what you must report. For that, ask your Tier II preparer or ADEQ’s Tier II line at 602-771-0397 or tier2@azdeq.gov.