Scope a project
Compliance services · Arizona

Workplace air monitoring for Arizona facilities.

Personal air sampling for welding fume, hexavalent chromium, silica, lead, solvents, dust and acid mists. We sample your employees through a normal shift, an accredited laboratory analyzes the samples, and you get a report that sets each result beside OSHA’s limits.

When you need it

  • A substance-specific OSHA standard applies. Hexavalent chromium, silica and lead each require an exposure assessment.
  • A process changed. New coatings, a new blasting medium, more welding or less ventilation.
  • A customer, insurer or corporate audit asks for exposure records.
  • An employee raised a concern or OSHA opened an inspection.
  • You rely on respirators and need to know what they are protecting against.

What we sample for

WorkTypical contaminants
Welding and cutting stainlessHexavalent chromium, manganese, welding fume metals
Plating and chemical processingHexavalent chromium, plating metals, acid mists
Painting and coatingSolvents such as toluene, xylene, MEK and MIBK; isocyanates
Blasting, cutting and grinding stone or concreteRespirable crystalline silica, total and respirable dust
Battery, foundry and firing-range workLead

Selected OSHA limits, as 8-hour time-weighted averages:

SubstanceAction levelPermissible exposure limit
Hexavalent chromium2.5 µg/m³5 µg/m³
Respirable crystalline silica25 µg/m³50 µg/m³
Lead30 µg/m³50 µg/m³

How a survey works

  1. Scope. You tell us the processes, the materials and the headcount. We review the safety data sheets and propose who to sample and for what.
  2. Fixed quote. Number of samples, methods and one price, with equipment and laboratory fees included.
  3. Sampling day. Pumps are calibrated before and after. Employees wear them in the breathing zone for a representative full shift while we observe the work and check the equipment.
  4. Laboratory. Samples go to an accredited laboratory under chain of custody, analyzed by the OSHA or NIOSH method for each substance.
  5. Report. Each result as an 8-hour average beside the action level and the limit, with what the standard requires next.

Employees represented by the monitoring can observe it, and the standards require you to tell them the results. The report is written so you can post it.

What it costs

Every survey is quoted as one fixed price before we schedule, with equipment and laboratory fees included. Tell us the site, the number of people or workstations and the deadline, and we reply within one business day. Arizona facilities only, with no travel charge in Maricopa County.

Related: Noise surveys for Arizona facilities, Arizona Tier II reporting and site maps and emergency and evacuation floor plans.

Questions
What is a workplace air monitoring survey?

A measurement of what your employees breathe during a normal shift. Each sampled employee wears a small pump that draws air through a filter or tube in the breathing zone. A laboratory analyzes the samples, and the report compares each result with OSHA’s action level and permissible exposure limit.

When does OSHA require it?

Several OSHA standards require an employer to assess exposure when a regulated substance is in use, among them hexavalent chromium, respirable crystalline silica and lead. For other substances, 29 CFR 1910.1000 sets limits an employer has to stay under, and sampling is how you show that you do.

What are the limits for hexavalent chromium, silica and lead?

As 8-hour time-weighted averages: hexavalent chromium has an action level of 2.5 and a permissible exposure limit of 5 micrograms per cubic meter; respirable crystalline silica, 25 and 50; lead, 30 and 50.

How many people do you sample?

Enough to represent each job with a likely exposure. We start with the employees expected to have the highest exposure in each task, such as welders, painters, plating and blasting operators. The quote lists the number of samples, so the price does not move.

Who analyzes the samples?

An accredited industrial hygiene laboratory, using the OSHA or NIOSH method for each substance. The lab report is included with ours.

What do I get?

A written report: who was sampled and what they were doing, the method and calibration, each result as an 8-hour average beside the action level and the limit, and what the standard asks you to do next when a result is over.

How long does it take?

One day on site for most facilities. Laboratory results take about one to two weeks, and the report follows.

What if a result is over the limit?

The report says so plainly and lists what the standard requires, such as more monitoring, controls, respirators or employee notification. Choosing and installing controls is your decision; we can sample again afterward to show the result.

Sources, checked 28 November 2026: OSHA 29 CFR 1910.1000 (air contaminants), 1910.1026 (chromium (VI)), 1910.1053 (respirable crystalline silica) and 1910.1025 (lead). In Arizona these federal standards are enforced by the state’s own program, ADOSH, which enforces 29 CFR 1910 for general industry. The limits on this page are the ones in those standards; check the standard itself before relying on a figure. RevealBuilt collects samples and reports results against OSHA’s limits. It is not a regulator, a laboratory or a medical provider, and it does not do asbestos or lead-paint inspections or medical surveillance.