What is measured and what is assumedWalls, doors and windows: iGUIDE floor plan data. Studs: placed where the laser hit framing at scan height, then drawn full height (315 found); darker bands are longer solid runs at scan height such as blocking or backing. Plumbing: the first upstairs bath and laundry are triangulated from two 360 photos, good to about 2 in.; the second upstairs bath and the main-floor bath come from one photo each, good to about 4 in. Electrical boxes (blue cubes, 82 found): detected by color and located by matching each box across three or more photos; boxes hidden from the cameras are missing, and the main floor is only partly covered. Recessed light housings (yellow, 25 found) are placed from the top-down ceiling maps, good to about 4 in. Ceilings: main 9.09 ft, 2nd 9.23 ft, averaged from room volumes. Floor-to-floor 11.0 ft and the 10:12 main roof pitch come from the vertical scans. The two front gables and the porch roof are shaped from drone photos, with pitch, overhangs and porch depth estimated. HVAC: ducts and register boots traced from top-down ceiling maps made from the photos, good to roughly 6 to 12 in.; duct height within the trusses, duct sizes and some junctions are estimated. Attic: trusses at 24 in. spacing as seen in the photos, with a simplified web pattern. Framing over the two front gables is drawn as a simplified over-framed set. Stairs: 18 risers over the measured floor height, on the tread lines from the plans; railings are not modeled. Main-floor water supply at the closet under the stairs is placed from two photos, good to about 4 in.; the water heater stand is approximate. Walk mode has no collision, so you can pass through framing. Lowering wall height hides the roof.